Level 1 · Starter build

Budget AGM Starter wiring diagram

The lowest-cost way into van electrics: an AGM battery, a modest solar panel and alternator charging running a small fridge, lights and USB sockets. Everything is sized conservatively so the budget bank lasts.

Get access to your wiring diagram by email

Build your plan in the calculator, then open the link we email you to view diagrams and download a PDF.

Create my plan

Read and adapt this wiring plan

This example starts with 710 Wh of daily appliance demand. Trace each charging source to the battery, then follow each protected supply to its load and back through the return path. The table makes the drawing searchable and gives you a record to compare with your actual cable routes.

Cable sizes and protective devices below are calculated planning outputs for the stated assumptions. They need checking against equipment manuals, installation conditions, available fault current and the applicable standards. Changing route length, battery voltage or appliance demand can change the result. An AWG conversion alone is not an ampacity check.

  1. Replace example appliance hours with your measured or intended use. Check both daily energy and simultaneous power.
  2. Place equipment to preserve ventilation, access and manufacturer clearances. Measure each real cable route before ordering.
  3. Review the supply, protective device, cable and terminal ratings as one circuit. Check battery and charger limits together.
  4. Have mains switching, earthing and protective-device operation assessed for every supply mode before use.
  5. Keep the final drawing, settings, photographs and commissioning results with the van. Recheck them after an upgrade.
Download this diagram, cable schedule and parts PDF

Cable schedule and assumed routes

ConnectionCurrentOne-way lengthCableFuseVoltage drop
House Battery Bank → Positive & Negative Busbars
positive
12.0 A0.5 m16 AWG15 A MEGA1.80%
Solar Array → MPPT Charge Controller
positive
10.0 A5 m10 AWGSee protection schedule3.00%
MPPT Charge Controller → Positive & Negative Busbars
positive
30.0 A1.5 m8 AWG40 A MIDI / MEGA at busbar2.20%
Starter Battery / Alternator → DC-DC Charger
positive
36.0 A5 m2 AWG50 A MIDI at starter battery2.10%
DC-DC Charger → Positive & Negative Busbars
positive
30.0 A1.5 m8 AWG40 A MIDI at busbar2.20%
Positive & Negative Busbars → 12 V Fuse Box
positive
12.0 A2 m10 AWG15 A MIDI at busbar1.80%
12 V Fuse Box → Compressor Fridge (Small)
positive
3.8 A4 m14 AWG5 A Blade, way #13.00%
12 V Fuse Box → LED Spot Lights
positive
1.7 A6 m16 AWG3 A Blade, way #23.00%
12 V Fuse Box → Water Pump
positive
5.0 A5 m14 AWG7.5 A Blade, way #34.90%
12 V Fuse Box → USB Sockets
positive
0.8 A4 m16 AWG2 A Blade, way #40.90%
House Battery Bank → Positive & Negative Busbars
negative
12.0 A0.5 m16 AWGSee protection schedule1.80%
Solar Array → MPPT Charge Controller
negative
10.0 A5 m10 AWGSee protection schedule3.00%
MPPT Charge Controller → Positive & Negative Busbars
negative
30.0 A1.5 m8 AWGSee protection schedule2.20%
Starter Battery / Alternator → DC-DC Charger
negative
36.0 A5 m2 AWGSee protection schedule2.10%
DC-DC Charger → Positive & Negative Busbars
negative
30.0 A1.5 m8 AWGSee protection schedule2.20%
Positive & Negative Busbars → 12 V Fuse Box
negative
12.0 A2 m10 AWGSee protection schedule1.80%
12 V Fuse Box → Compressor Fridge (Small)
negative
3.8 A4 m14 AWGSee protection schedule3.00%
12 V Fuse Box → LED Spot Lights
negative
1.7 A6 m16 AWGSee protection schedule3.00%
12 V Fuse Box → Water Pump
negative
5.0 A5 m14 AWGSee protection schedule4.90%
12 V Fuse Box → USB Sockets
negative
0.8 A4 m16 AWGSee protection schedule0.90%
Starter Battery / Alternator → DC-DC Charger
signal
0.5 A5 m16 AWG5 A Blade at ignition feed0.00%
MPPT Charge Controller → House Battery Bank
signal
0.0 A1.5 m16 AWGSee protection schedule0.00%
Positive & Negative Busbars → Chassis Bond
protective-earth
0.0 A1 m4 AWGSee protection schedule0.00%

Appliance branch circuits

LoadCurrentRouteCableFuse
Compressor Fridge (Small)3.8 A4 m14 AWG5 A
LED Spot Lights1.7 A6 m16 AWG3 A
Water Pump5.0 A5 m14 AWG7.5 A
USB Sockets0.8 A4 m16 AWG2 A

Protection and installation parts

  • MEGA fuse 15 A + holder — 1; Main battery protection
  • Battery isolator switch — 1; 100 A+ continuous rating
  • Battery interconnect cables — 2; 1 mm² — identical length & cross-section per Victron guidance
  • Busbar pair (+/−) — 1 pair; ≥ 150 A, insulated covers
  • PV isolator switch — 1; DC-rated, ≥ 56 V
  • Solar roof gland + MC4 connectors — 1 set; Waterproof cable entry
  • MC4 extension cable pair — ≈ 2; Panel-to-panel and string-to-gland runs, UV-rated
  • MIDI fuse holders + fuses — 2; 50 A and 40 A for DC-DC run
  • 6-way 12 V blade fuse box — 1; With negative bus
  • 12 V blade fuse assortment — 1 set; 5 A, 3 A, 7.5 A, 2 A
  • D+ signal wire 0.75 mm² — ≈ 5 m; Ignition feed → DC-DC charger D+ terminal
  • 25 mm² cable — ≈ 11 m total; Red + black pair (lengths include 10 % spare)
  • 16 mm² cable — ≈ 3 m total; Red + black pair (lengths include 10 % spare)
  • 6 mm² cable — ≈ 7 m total; Red + black pair (lengths include 10 % spare)
  • 4 mm² cable — ≈ 16 m total; Red + black pair (lengths include 10 % spare)
  • 1.5 mm² cable — ≈ 40 m total; Red + black pair (lengths include 10 % spare)
  • 1 mm² cable — ≈ 46 m total; Red + black pair (lengths include 10 % spare)
  • Crimp lugs & ferrules — assorted; Sized to each cable; use a proper crimper
  • Heat shrink, grommets, cable clips — assorted; Abrasion protection everywhere a cable touches metal

Assumptions to review

  • System voltage 12 V (12 V nominal AGM). Voltage drop calculated round-trip (2 × run length) with copper resistivity 0.0175 Ω·mm²/m.
  • Voltage drop targets: ≤ 2.5 % main battery/charge runs (Victron), ≤ 3 % critical circuits (fridge, electronics), ≤ 5 % non-critical circuits (Blue Sea 3 %/10 % tiers, drawn conservatively).
  • Cable cross-sections are shown in mm² (SI). US builders: 6 mm² ≈ 9 AWG, 10 mm² ≈ 7 AWG, 16 mm² ≈ 5 AWG, 25 mm² ≈ 3 AWG, 35 mm² ≈ 2 AWG — confirm ampacity against NEC / ABYC tables for your install.
  • Fuses sized ≥ 1.25 × continuous load and ≤ cable ampacity, so the fuse always protects the cable.
  • Solar panel Voc ≈ 23 V and Isc ≈ W ÷ 19 estimated for typical "12 V" panels; cold-weather Voc factor 1.2. Check your actual panel datasheet.
  • Inverter DC current = W ÷ (11.5 V × 0.87 efficiency). Where a product manual states cable/fuse sizes, the manual takes precedence.
  • Circuit run lengths are typical-van defaults (fridge 4 m, lighting 6 m, etc.) — measure yours and resize if longer.
  • US solar yield assumed 4 peak sun hours at 72 % system efficiency (annual average).

References and next steps