Heavy Off-Grid (Induction Cooking) wiring diagram

The no-gas flagship build: induction cooking, coffee machine, kettle and Starlink on a big lithium bank with a large solar array. The most demanding system a 12V van can sensibly run — every cable and fuse matters here.

Get access to your wiring diagram by email

Build your plan in the calculator, then open the link we email you to view diagrams and download a PDF.

Create my plan

Read and adapt this wiring plan

This example starts with 3774 Wh of daily appliance demand. Trace each charging source to the battery, then follow each protected supply to its load and back through the return path. The table makes the drawing searchable and gives you a record to compare with your actual cable routes.

Cable sizes and protective devices below are calculated planning outputs for the stated assumptions. They need checking against equipment manuals, installation conditions, available fault current and the applicable standards. Changing route length, battery voltage or appliance demand can change the result. An AWG conversion alone is not an ampacity check.

  1. Replace example appliance hours with your measured or intended use. Check both daily energy and simultaneous power.
  2. Place equipment to preserve ventilation, access and manufacturer clearances. Measure each real cable route before ordering.
  3. Review the supply, protective device, cable and terminal ratings as one circuit. Check battery and charger limits together.
  4. Have mains switching, earthing and protective-device operation assessed for every supply mode before use.
  5. Keep the final drawing, settings, photographs and commissioning results with the van. Recheck them after an upgrade.
Download this diagram, cable schedule and parts PDF

Cable schedule and assumed routes

ConnectionCurrentOne-way lengthCableFuseVoltage drop
Leisure Battery Bank → Positive & Negative Busbars
positive
112.0 A0.5 m25 mm²150 A Class T (high interrupt rating)0.30%
Solar Array → MPPT Charge Controller
positive
22.0 A5 m4 mm²20 A Inline MC42.70%
MPPT Charge Controller → Positive & Negative Busbars
positive
60.0 A1.5 m16 mm²80 A MIDI / MEGA at busbar0.80%
Starter Battery / Alternator → DC-DC Charger
positive
72.0 A5 m50 mm²100 A MIDI at starter battery2.10%
DC-DC Charger → Positive & Negative Busbars
positive
60.0 A1.5 m16 mm²80 A MIDI at busbar0.80%
Positive & Negative Busbars → Inverter
positive
100.0 A1 m25 mm²125 A Class T0.50%
Inverter → AC Consumer Unit (RCD + MCBs)
ac
9.0 A1 m2.5 mm²See protection schedule0.00%
AC Consumer Unit (RCD + MCBs) → Induction Hob
ac
9.0 A4 m2.5 mm²See protection schedule0.00%
AC Consumer Unit (RCD + MCBs) → Travel Kettle
ac
5.0 A4 m2.5 mm²See protection schedule0.00%
AC Consumer Unit (RCD + MCBs) → Coffee Machine
ac
5.0 A4 m2.5 mm²See protection schedule0.00%
AC Consumer Unit (RCD + MCBs) → Laptop
ac
1.0 A4 m2.5 mm²See protection schedule0.00%
Positive & Negative Busbars → 24→12 V Converter
positive
12.0 A1 m1 mm²15 A MIDI at busbar1.60%
24→12 V Converter → 12 V Fuse Box
positive
21.0 A0.5 m6 mm²30 A MIDI at converter output1.90%
12 V Fuse Box → Compressor Fridge (Large)
positive
5.1 A4 m2.5 mm²7.5 A Blade, way #12.20%
12 V Fuse Box → LED Strip Lights
positive
0.9 A6 m1 mm²2 A Blade, way #21.50%
12 V Fuse Box → LED Spot Lights
positive
1.6 A6 m1 mm²2 A Blade, way #32.60%
12 V Fuse Box → Water Pump
positive
4.7 A5 m1.5 mm²7.5 A Blade, way #44.30%
12 V Fuse Box → Roof Vent Fan
positive
1.4 A3 m1 mm²2 A Blade, way #51.10%
12 V Fuse Box → Diesel Heater
positive
2.0 A4 m1 mm²3 A Blade, way #62.20%
12 V Fuse Box → Starlink Mini
positive
3.1 A4 m1.5 mm²5 A Blade, way #72.30%
12 V Fuse Box → USB Sockets
positive
0.8 A4 m1 mm²2 A Blade, way #80.90%
12 V Fuse Box → Inverter Standby
positive
1.2 A4 m1 mm²2 A Blade, way #91.30%
Leisure Battery Bank → Positive & Negative Busbars
negative
112.0 A0.5 m25 mm²See protection schedule0.30%
Solar Array → MPPT Charge Controller
negative
22.0 A5 m4 mm²See protection schedule2.70%
MPPT Charge Controller → Positive & Negative Busbars
negative
60.0 A1.5 m16 mm²See protection schedule0.80%
Starter Battery / Alternator → DC-DC Charger
negative
72.0 A5 m50 mm²See protection schedule2.10%
DC-DC Charger → Positive & Negative Busbars
negative
60.0 A1.5 m16 mm²See protection schedule0.80%
Positive & Negative Busbars → Inverter
negative
100.0 A1 m25 mm²See protection schedule0.50%
Positive & Negative Busbars → 24→12 V Converter
negative
12.0 A1 m1 mm²See protection schedule1.60%
24→12 V Converter → 12 V Fuse Box
negative
21.0 A0.5 m6 mm²See protection schedule1.90%
12 V Fuse Box → Compressor Fridge (Large)
negative
5.1 A4 m2.5 mm²See protection schedule2.20%
12 V Fuse Box → LED Strip Lights
negative
0.9 A6 m1 mm²See protection schedule1.50%
12 V Fuse Box → LED Spot Lights
negative
1.6 A6 m1 mm²See protection schedule2.60%
12 V Fuse Box → Water Pump
negative
4.7 A5 m1.5 mm²See protection schedule4.30%
12 V Fuse Box → Roof Vent Fan
negative
1.4 A3 m1 mm²See protection schedule1.10%
12 V Fuse Box → Diesel Heater
negative
2.0 A4 m1 mm²See protection schedule2.20%
12 V Fuse Box → Starlink Mini
negative
3.1 A4 m1.5 mm²See protection schedule2.30%
12 V Fuse Box → USB Sockets
negative
0.8 A4 m1 mm²See protection schedule0.90%
12 V Fuse Box → Inverter Standby
negative
1.2 A4 m1 mm²See protection schedule1.30%
Starter Battery / Alternator → DC-DC Charger
signal
0.5 A5 m0.75 mm²5 A Blade at ignition feed0.00%
Positive & Negative Busbars → Chassis Bond
protective-earth
0.0 A1 m16 mm²See protection schedule0.00%

Appliance branch circuits

LoadCurrentRouteCableFuse
Compressor Fridge (Large)5.1 A4 m2.5 mm²7.5 A
LED Strip Lights0.9 A6 m1 mm²2 A
LED Spot Lights1.6 A6 m1 mm²2 A
Water Pump4.7 A5 m1.5 mm²7.5 A
Roof Vent Fan1.4 A3 m1 mm²2 A
Diesel Heater2.0 A4 m1 mm²3 A
Starlink Mini3.1 A4 m1.5 mm²5 A
USB Sockets0.8 A4 m1 mm²2 A
Inverter Standby1.2 A4 m1 mm²2 A

Protection and installation parts

  • Class fuse 150 A + holder — 1; Main battery protection
  • Battery isolator switch — 1; 150 A+ continuous rating
  • Battery interconnect cables — 1; 25 mm² — identical length & cross-section per Victron guidance
  • Busbar pair (+/−) — 1 pair; ≥ 150 A, insulated covers
  • MC4 inline fuse 20 A — 2; One per parallel string
  • PV isolator switch — 1; DC-rated, ≥ 83 V
  • Solar roof gland + MC4 connectors — 1 set; Waterproof cable entry
  • MC4 Y-branch connector pair — 1 pair(s); Joins 2 parallel strings into one PV+ / PV− pair
  • MC4 extension cable pair — ≈ 4; Panel-to-panel and string-to-gland runs, UV-rated
  • MIDI fuse holders + fuses — 2; 100 A and 80 A for DC-DC run
  • Class T fuse 125 A + holder — 1; Inverter supply
  • Victron Orion-Tr 24/12-30 (360W) — 1; 24→12 V converter for the loads rail
  • 11-way 12 V blade fuse box — 1; With negative bus
  • 12 V blade fuse assortment — 1 set; 7.5 A, 2 A, 3 A, 5 A
  • D+ signal wire 0.75 mm² — ≈ 5 m; Ignition feed → DC-DC charger D+ terminal
  • 50 mm² cable — ≈ 11 m total; Red + black pair (lengths include 10 % spare)
  • 25 mm² cable — ≈ 4 m total; Red + black pair (lengths include 10 % spare)
  • 16 mm² cable — ≈ 9 m total; Red + black pair (lengths include 10 % spare)
  • 6 mm² cable — ≈ 2 m total; Red + black pair (lengths include 10 % spare)
  • 4 mm² cable — ≈ 11 m total; Red + black pair (lengths include 10 % spare)
  • 2.5 mm² cable — ≈ 18 m total; Red + black pair (lengths include 10 % spare)
  • 1.5 mm² cable — ≈ 40 m total; Red + black pair (lengths include 10 % spare)
  • 1 mm² cable — ≈ 121 m total; Red + black pair (lengths include 10 % spare)
  • Crimp lugs & ferrules — assorted; Sized to each cable; use a proper crimper
  • Heat shrink, grommets, cable clips — assorted; Abrasion protection everywhere a cable touches metal

Assumptions to review

  • System voltage 24 V (25.6 V nominal LiFePO4). Voltage drop calculated round-trip (2 × run length) with copper resistivity 0.0175 Ω·mm²/m.
  • Voltage drop targets: ≤ 2.5 % main battery/charge runs (Victron), ≤ 3 % critical circuits (fridge, electronics), ≤ 5 % non-critical circuits (Blue Sea 3 %/10 % tiers, drawn conservatively).
  • Cable ampacities from UK thin-wall (≤ 6 mm²) and Hi-Flex battery cable (≥ 10 mm²) published ratings, free-air.
  • Fuses sized ≥ 1.25 × continuous load and ≤ cable ampacity, so the fuse always protects the cable.
  • Solar panel Voc ≈ 23 V and Isc ≈ W ÷ 19 estimated for typical "12 V" panels; cold-weather Voc factor 1.2. Check your actual panel datasheet.
  • Inverter DC current = W ÷ (23 V × 0.87 efficiency). Where a product manual states cable/fuse sizes, the manual takes precedence.
  • Circuit run lengths are typical-van defaults (fridge 4 m, lighting 6 m, etc.) — measure yours and resize if longer.
  • UK solar yield assumed 2.8 peak sun hours at 72 % system efficiency (annual average).

References and next steps

Read the wiring safety guide or calculate your own appliance plan.

Embed this diagram on your website