An inverter turns your 12V battery power into the 120V AC your household appliances expect. It's what lets you run a microwave, induction cooktop, or power tools off-grid — without needing a campground hookup.
But inverters also pull enormous current from your battery, require very thick cables, and produce real household-voltage power on their output that can kill if wired incorrectly. This guide covers everything: whether you actually need one, which type to buy, how to size it, what you can realistically run, how to wire it to ABYC and NEC standards, and what can go wrong.
For the complete system context, see the van electrical system guide.
Size your inverter to your loads
Tell us your 120V appliances and we'll size the inverter and its cabling — free.
Do You Actually Need One?
This is the most important question in inverter selection, and the answer is often "no."
You DON'T need an inverter for:
-
USB-C laptop charging: Most MacBooks (2017+), Dell XPS, ThinkPads, HP Spectre, Surface Pro, and most modern laptops charge via USB-C PD at 45W, 65W, or 100W. A 12V USB-C GaN charger (Anker 715, Satechi 108W) charges these efficiently directly from 12V — no inverter, no 120V needed. This is actually slightly more efficient than going 12V → 120V → laptop charger → laptop.
-
Phone, tablet, camera charging: Use 12V USB sockets or a 12V USB hub. Negligible draw.
-
12V compressor fridge: Runs directly on 12V — purpose-built for off-grid use.
-
LED lighting, diesel heater, water pump, vent fan: All 12V native.
-
CPAP (many models): Most modern CPAP machines (ResMed AirSense, Philips DreamStation) have a 12V DC adapter available from the manufacturer. Using the 12V adapter directly is ~30% more efficient than running through an inverter. Check your specific model before assuming you need 120V.
You DO need an inverter for:
- Microwave (most are 120V-only, 800–1,200W draw)
- Induction cooktop (120V, 1,500–1,800W per burner)
- Standard hair dryer, hair straighteners
- Full-size blender (Vitamix, Blendtec)
- Power tools with 120V motors (drill, jigsaw, circular saw)
- Laptop with only a 120V barrel charger and no USB-C option
- Pressure cooker / Instant Pot
- Any appliance that only comes with a US three-prong 120V plug and has no 12V alternative
The more you can shift to 12V native loads, the smaller (and cheaper) the inverter you need.
Pure Sine Wave: Non-Negotiable
Buy a pure sine wave inverter. Not modified sine wave. This isn't a preference — it's a technical requirement for most loads you'd actually want to run in a van.
Understanding the Waveforms
Utility power from the grid is a smooth, continuously varying 60Hz AC sine wave, peaking at approximately ±170V (the rated 120V is RMS, not peak). Every appliance with a 120V plug is designed around this waveform.
Pure sine wave inverters produce a genuine smooth sine wave, electronically synthesized. Identical to grid power. All appliances work correctly.
Modified sine wave (MSW) inverters produce a stepped, blocky approximation of a sine wave — it alternates at 60Hz but with a staircase waveform instead of a smooth curve. It's technically AC at the right frequency, but the harmonic content is very different from grid power.
What Modified Sine Wave Damages or Degrades
Microprocessor-controlled appliances: Modern microwaves, variable-speed fans, inverter-type air conditioners, and any appliance where a microprocessor controls the operation may malfunction, display error codes, or fail prematurely on MSW power.
Laptop switch-mode power supplies: While most laptop power bricks technically operate on MSW, they run less efficiently (more heat), and the added harmonic stress reduces their lifespan. Some will make an audible buzzing sound.
CPAP machines: Many CPAP machines explicitly warn against MSW in their documentation. Some won't run at all; others run but develop premature motor failure.
Battery chargers with microprocessors: The chargers for cordless tool batteries, camera batteries, and similar devices may malfunction or charge incorrectly.
Induction motors: Electric motors (in fans, pumps, compressors) run less efficiently and hotter on MSW — wasting energy and reducing component life.
Audio equipment: MSW introduces 60Hz and harmonic buzz through audio systems.
The bottom line: The price difference between a quality MSW and a quality pure sine wave inverter at the same power rating is $50–$150. The compatibility risk of MSW is not worth it for any appliance you'd actually run in a van. Buy pure sine wave.
Understanding Inverter Power Ratings
Continuous vs. Peak Power
Every inverter has two ratings:
Continuous (rated) power: What the inverter can deliver indefinitely without overheating. This is the spec that determines whether your appliance will run. A 1,000W continuous inverter can power any combination of loads up to 1,000W without issue.
Peak (surge) power: What the inverter can deliver for a brief period (typically 5–20 seconds) during motor startup. Usually 2× the continuous rating.
Motor-driven appliances draw much more current at startup than during steady-state operation:
| Appliance | Steady-State Watts | Startup Surge |
|---|---|---|
| Drill (1/2" corded) | 500W | 1,500W+ |
| Circular saw (7-1/4") | 1,200W | 3,500W+ |
| Blender (Vitamix A3500) | 1,500W (peak) | 2,400W |
| Window AC (5,000 BTU) | 500W | 1,200W |
| CPAP (with heated humidifier) | 200W | 300W |
| Microwave (1,000W rated) | 1,050–1,200W input | 1,200W (no motor) |
For motor loads, your inverter's peak rating must exceed the startup surge — not just the steady-state watts.
Inverter Efficiency
Inverters aren't 100% efficient — they lose some energy as heat during conversion. Quality pure sine wave inverters are 85–93% efficient depending on load.
Battery draw formula: Battery amps = Appliance watts ÷ (Battery voltage × Inverter efficiency)
Example: 1,000W microwave on a 12V system with 90% efficient inverter: = 1,000 ÷ (12.8 × 0.90) = 86.8A from the battery
This is why inverter cables must be so thick — 87A continuous requires 2 AWG minimum for a 3-foot run, or 1/0 AWG for anything longer.
Standby Draw
An inverter powered on but with no load still consumes power to maintain its internal circuits. Typical standby draws:
| Inverter | Standby Draw |
|---|---|
| Budget 1,000W inverter | 15–30W |
| Victron Phoenix 12/800 | ~7W (6W in power-save mode) |
| Victron Phoenix 12/1200 | ~8W (2W in power-save mode) |
| Victron MultiPlus 12/1600 | ~14W |
At 15W standby over 8 hours, you lose 120Wh — about 10% of a 200Ah battery's daily budget. Turn the inverter off when not using it. Install a remote on/off switch so you can cut power from your bed without going to the inverter's location.
Victron Phoenix inverters have a power-save mode that reduces standby to 2–6W by monitoring for an AC load demand and waking up only when one is detected. The wake-up time is ~20ms — appliances typically don't notice.
Sizing Your Inverter: The Process
- List every 120V appliance you want to run
- Note the wattage of each (from the label, not the plug fuse rating)
- Determine what you'd run simultaneously
- Add simultaneous watts + 25% headroom = minimum continuous rating
- Check startup surge of any motor loads against the inverter's peak rating
Common sizing scenarios:
| Build Type | What You Run | Inverter Size |
|---|---|---|
| Remote worker, no cooking | Laptop (120V barrel) + monitors | 500W |
| Coffee + laptop | Nespresso (1,200W) + laptop | 1,500W |
| Hair dryer user | Hair dryer (1,875W max) | 2,000W |
| Cooking with induction | One induction burner (1,800W) | 2,500W |
| Power tools (occasional) | Drill (500W) + surge | 1,500W (if 3,000W peak) |
| Full kitchen | Induction + microwave (not simultaneously) | 2,000W |
Don't oversize for the sake of it. A 2,000W inverter on standby draws more quiescent power than a 1,000W model. If your actual peak draw is 600W, a 1,000W inverter with comfortable headroom is the right choice.
US Product Recommendations
Victron Phoenix (The Reference Standard)
The most popular inverter choice in the US van life community. Pure sine wave, wide voltage range (9.5–17V input for 12V models), excellent build quality, integrates with Victron monitoring ecosystem.
| Model | Continuous | Peak | Weight | US Price (2026) |
|---|---|---|---|---|
| Phoenix 12/250 | 200W | 400W | 2.9 lbs | ~$120 |
| Phoenix 12/375 | 300W | 600W | 3.3 lbs | ~$140 |
| Phoenix 12/500 | 400W | 900W | 4.2 lbs | ~$160 |
| Phoenix 12/800 | 650W | 1,600W | 5.5 lbs | ~$200 |
| Phoenix 12/1200 | 1,000W | 2,400W | 9.7 lbs | ~$250 |
| Phoenix 12/1600 | 1,350W | 3,200W | 11.5 lbs | ~$310 |
| Phoenix 12/2000 | 1,700W | 4,000W | 13.2 lbs | ~$380 |
The 12/1200 (1,000W continuous) handles a Nespresso, hair straighteners, laptop, and most van life loads. The 12/1600 adds hair dryer capability. The 12/2000 handles a single induction burner at moderate power settings.
All Phoenix models have a VE.Direct port for monitoring and a remote on/off terminal for a panel-mounted switch.
Victron MultiPlus (Inverter/Charger)
The MultiPlus combines a pure sine wave inverter and a shore power converter/charger in one unit, with a built-in automatic transfer switch.
When shore power is connected: the MultiPlus passes shore power through to loads and uses excess capacity to charge the battery. When shore power disconnects: the MultiPlus instantly (within 20ms) switches to inverter mode.
| Model | Inverter Continuous | Shore Charger | US Price (2026) |
|---|---|---|---|
| MultiPlus 12/800/35 | 700W | 35A | ~$450 |
| MultiPlus 12/1200/50 | 1,000W | 50A | ~$560 |
| MultiPlus 12/1600/70 | 1,400W | 70A | ~$660 |
| MultiPlus 12/2000/80 | 1,800W | 80A | ~$820 |
| MultiPlus 12/3000/120 | 2,500W | 120A | ~$1,150 |
The MultiPlus eliminates the need for a separate shore power converter/charger, and the automatic transfer switching is seamless. For any build where both shore power and inverter capability are needed, the MultiPlus is a cleaner solution than separate units.
Mid-Range Pure Sine Wave
| Model | Continuous | US Price (2026) |
|---|---|---|
| Renogy 1000W PSW | 1,000W | ~$160 |
| Renogy 2000W PSW | 2,000W | ~$280 |
| AIMS 1250W PSW | 1,250W | ~$200 |
| Go Power GP-1750HD | 1,750W | ~$350 |
These work well as standalone inverters without Victron ecosystem integration. The Renogy units in particular are popular in the van life community as a cost-effective pure sine wave option.
Wiring the Inverter: DC Side
The inverter's DC cables carry the highest current in the entire van system. Wiring them correctly is critical — undersized cables are a fire risk.
Cable Length and AWG
Inverter cables must be as short as possible — this is the most important design constraint for inverter installation. Mount the inverter close to the bus bar or battery.
AWG sizing for 12V inverter DC cables (ABYC E-11 compliant, tinned marine wire):
| Inverter Continuous Rating | Max DC Current (90% eff.) | Cable Length (each run) | Min AWG |
|---|---|---|---|
| 300W | 26A | Up to 5 ft | 10 AWG |
| 500W | 43A | Up to 5 ft | 8 AWG |
| 800W | 69A | Up to 4 ft | 6 AWG |
| 1,000W | 87A | Up to 3 ft | 4 AWG |
| 1,000W | 87A | 3–5 ft | 2 AWG |
| 1,500W | 130A | Up to 3 ft | 2 AWG |
| 2,000W | 174A | Up to 3 ft | 1/0 AWG |
| 2,000W | 174A | 3–5 ft | 2/0 AWG |
| 3,000W | 261A | Up to 3 ft | 3/0 AWG |
Use fine-stranded, marine-grade tinned copper cable — not solid-core, not standard automotive wire. The high current and vibration environment demand flexible, corrosion-resistant cable.
Fusing the DC Side
A dedicated fuse must be placed between the positive bus bar and the inverter, within 18 inches of the bus bar (ideally closer). This protects the heavy inverter cable.
Use an ANL fuse for inverters up to about 2,000W, or a Class T fuse for larger systems. The fuse rating must be:
- Greater than the inverter's maximum current draw (to not nuisance-trip)
- Less than or equal to the cable's ampacity (to protect the cable)
| Inverter Continuous | Max Current | Min AWG Cable | ANL Fuse |
|---|---|---|---|
| 1,000W | 87A | 4 AWG | 100A |
| 1,500W | 130A | 2 AWG | 150A |
| 2,000W | 174A | 1/0 AWG | 200A |
| 3,000W | 261A | 3/0 AWG | 300A |
Inverter Placement
Close to the battery/bus bar. This is the most important placement factor. Shorter cables = smaller voltage drop = more power at the inverter input. Long inverter cables not only waste power — they're more expensive and harder to route correctly.
Ventilated location. Inverters generate significant heat at high loads. Mount in a location with airflow — not inside a sealed cabinet without ventilation gaps at top and bottom. The Victron Phoenix fan activates at a temperature threshold; ensure the fan exhaust isn't blocked.
Accessible for the remote switch cable. The remote on/off connection (a small pair of terminals on the inverter) connects to a panel-mounted switch. This lets you control the inverter from your living area without accessing the inverter directly.
See how to install an inverter in a van for the complete step-by-step guide.
The 120V Output Side: Safety Requirements
This is where van electrical work becomes as serious as home electrical work. The inverter's 120V output is identical in hazard level to any household outlet.
GFCI Protection
GFCI (Ground Fault Circuit Interrupter) protection is mandatory for all 120V outlets in a van. NEC Article 551 requires GFCI protection in recreational vehicles; ABYC standards require it in marine/vehicle electrical systems.
A GFCI device monitors the current balance between the hot (black) and neutral (white) conductors. If they differ by more than 5mA (indicating current is taking a path through a person to ground), the GFCI opens the circuit within 25 milliseconds — before a lethal shock can occur.
Options:
- GFCI outlet at each receptacle — protects only that outlet (and any outlets downstream of it)
- GFCI breaker in the breaker panel — protects the entire circuit
For most van builds with 2–4 outlets, GFCI outlets are the simpler solution.
Breaker Panel
For more than two 120V circuits, install a small breaker panel between the inverter and your outlets. This provides:
- An overall ON/OFF disconnect for all 120V circuits
- Individual circuit breakers (MCBs) per circuit — protects the 120V wiring and enables easy isolation
A 4-circuit or 6-circuit RV-style panel is appropriate for most vans. Wire sizing for 120V circuits: minimum 12 AWG for 20A circuits (the standard for most van appliance circuits). Use 12 AWG three-conductor wire (NM-B/Romex in protected interior locations, or THHN in conduit).
Grounding and the Neutral-Earth Bond
The 120V safety circuit depends on correct grounding. In a van running on inverter power:
The inverter's 120V output neutral must be bonded to the vehicle chassis (which serves as earth). Without this bond, a fault between a 120V conductor and the van body doesn't trip the GFCI — the van body sits at 120V relative to true ground, and anyone touching the van while standing on earth could be shocked.
Most pure sine wave inverters include this bond internally. Verify in your inverter's manual before adding an external neutral-earth link — a double bond can cause issues. Victron Phoenix and MultiPlus both include the neutral-earth bond.
When both inverter and shore power are present:
Shore power's neutral is bonded to earth at the pedestal (by the campground's electrical system). The inverter has its own internal bond. These two bonds must never be simultaneously active — it causes a ground loop.
A Victron MultiPlus manages this automatically: when shore power is connected, it transfers the neutral-earth bond to the shore power reference. When on inverter, it uses its internal bond. For separate inverter + shore power systems, an automatic or manual transfer switch ensures only one bond is active at a time.
NEC Article 551 Compliance
The National Electrical Code Article 551 covers electrical systems in recreational vehicles and converted vehicles. Key requirements relevant to van conversions:
- All 120V wiring must be in appropriate raceway (conduit) or use listed cable types
- Minimum 12 AWG conductors for 20A circuits
- GFCI protection on all 120V outlets
- Shore power inlet must be in a weatherproof location
- Transfer switch or equivalent required if both inverter and shore power feed the same outlets
- All work must be performed by a qualified person or inspected by a licensed electrician
The 12V side has no specific NEC requirements (NEC covers premises wiring, not 12V systems), but ABYC E-11 standards for marine 12V systems are the recognized best practice for van electrical builds.
Running Specific Appliances
Microwave
A 900W microwave requires approximately 1,050–1,200W of input power (magnetrons aren't very efficient). Size for 1,500W inverter to have headroom.
Battery drain: 1,100W ÷ (12.8V × 0.90 efficiency) = 95.5A from battery.
A 200Ah LiFePO4 (160Ah usable) runs the microwave for: 160Ah ÷ 95.5A = 1.68 hours at continuous use. For 6 minutes of microwave use per day: 95.5A × (6÷60 hours) = 9.5Ah/day — entirely manageable.
Induction Cooktop
Single-burner induction hobs at maximum power draw 1,500–1,800W. For comfortable margin, use a 2,000W+ inverter.
At 1,800W, a 200Ah LiFePO4 can cook continuously for: 160Ah ÷ (1,800 ÷ 12.8 ÷ 0.90) = 1.02 hours at full power.
For a 20-minute dinner cook: 156A × (20÷60 hours) = 52Ah consumed. That's ~33% of a 200Ah battery for one cooking session. Induction cooking is practical for van life with a large battery (300Ah+) or shore power access, but it's expensive in battery terms.
Practical approach: Use induction at reduced power (600–800W, which most hobs support). At 700W draw: 700 ÷ (12.8 × 0.90) = 60.8A. 200Ah LiFePO4 handles 2.6 hours of cooking at this power level — much more practical for daily use.
See what can a 2,000W inverter run for a complete analysis.
Hair Dryer
Standard hair dryers: 1,200–1,875W. A 1,200W dryer on a 2,000W inverter has comfortable headroom.
For 10 minutes of use per day at 1,200W: 1,200 ÷ (12.8 × 0.90) = 104A draw × (10÷60 hours) = 17.3Ah from the battery. Very manageable.
Power Tools
Most corded tools work on pure sine wave inverters, but their startup surge can be significant. A 7-1/4" circular saw (1,200W rated) may surge to 3,500W at startup — requiring a 2,000W+ continuous inverter with 4,000W+ surge rating.
For occasional DIY use in a van, many builders prefer a cordless tool setup for most tasks, reserving the inverter for tools that don't have good battery alternatives.
Troubleshooting
Inverter shuts down immediately under load:
-
Check battery voltage under load — if it sags below the inverter's low-voltage cutoff (typically 10.5V for a 12V model), the inverter shuts down for battery protection. This indicates either a discharged battery, or undersized cables causing excessive voltage drop under high current.
-
Check that the load's startup surge doesn't exceed the inverter's peak rating. A large motor's surge can trip the inverter even if steady-state watts are within the continuous rating.
-
Check the ANL fuse — a fuse that's been weakened by a previous overcurrent event may trip at lower than rated current.
GFCI tripping when inverter activates:
Some inverters have measurable leakage through their EMI filter capacitors. If this leakage exceeds 5mA, the GFCI detects it as a fault and trips. The first diagnostic is to try a GFCI rated for "equipment protection" rather than "personnel protection" — these are less sensitive (typically 30mA trip threshold vs 5mA). Check that the inverter's neutral-earth bond is correctly installed and that no other neutral-earth bond is present simultaneously.
120V outlets have correct voltage but appliances won't run:
Verify the inverter is producing pure sine wave (some inverters can develop output faults). If possible, use an outlet tester with a voltage display to verify output quality. Modified sine wave (in a supposedly pure sine unit) indicates an internal inverter fault.
Inverter overheating and shutting down:
Insufficient ventilation around the inverter. The inverter fan may be blocked, or the inverter is in a sealed enclosure without airflow. Relocate to a ventilated space or add ventilation gaps to the enclosure. Check that the inverter isn't in direct sunlight or near a heat source.
Related Guides
- Complete van electrical system guide
- House battery guide — sizing the battery bank your inverter draws from
- Charging systems guide — replacing what the inverter uses
- Wiring & safety guide — AWG cable sizing and fusing
FAQ
What size inverter do I need for a van?
For occasional coffee machine use: 1,500W. For hair dryer: 2,000W. For induction cooking: 2,000–2,500W. For laptop and devices only (if they can't charge via USB-C): 500W. Most builders land on a 1,000–1,600W pure sine wave inverter as a practical all-rounder.
Pure sine or modified sine wave?
Always pure sine. Modified sine wave can damage microprocessors, cause motors to run hot, buzz through audio equipment, and make CPAP machines malfunction. The extra $50–$150 for pure sine is not negotiable.
Do I need an inverter in my van?
Only if you run genuine 120V-only appliances: microwave, induction cooktop, power tools, hair dryer. Phones and most modern laptops charge via USB-C from 12V. Many efficient van builds skip the inverter entirely and stay 12V native.
How long can I run a 1,000W inverter on a 200Ah LiFePO4?
At full load (1,000W): approximately 1.7 hours. At half load (500W): approximately 3.4 hours. At light load (100W): approximately 16 hours. (These assume 80% usable DoD and 90% inverter efficiency.)
Can I run shore power and the inverter at the same time?
Not into the same outlet circuit — the two 120V sources must be properly switched (either by a MultiPlus's automatic transfer relay or a manual transfer switch). Connecting both to the same outlets creates a dangerous backfeed situation. A Victron MultiPlus handles this correctly by design; separate inverter + shore power setups need an explicit transfer switch.
What's the minimum wiring I need for an inverter?
At minimum: correct AWG DC cables from battery/bus bar to inverter (see table above), a properly rated ANL fuse at the bus bar end within 18 inches of the tap-off point, correct AWG 120V wiring from inverter output to GFCI outlet(s), and a chassis ground connection from the inverter's ground terminal. That's a functional and safe minimum installation.
Roam Wired
Roam Wired turns campervan research into practical plans. We publish transparent guidance, a free electrical design tool and marketplace resources for UK and US van builders.
About our approach